Glossary of battery storage, EMS, PPC, and solar monitoring terms

One sentence definitions of the terms a developer, asset owner, or utility meets in battery storage controls, grid interconnection, solar monitoring, tariffs, and the standards that govern them. Each term has its own page with context, related terms, a primary source, and a link to the guide that covers it in depth.

60 terms. Updated . Written by the engineers who build and operate these systems.

Control stack

Battery energy storage system (BESS)
A battery energy storage system (BESS) is a battery, its power conversion system, and its controls, installed to store electricity and deliver it back to a site or the grid on command.
Read more
Battery management system (BMS)
A battery management system (BMS) is the controller inside a battery that measures cells, protects them, and publishes the charge and discharge limits the battery can safely accept.
Read more
Data acquisition system (DAS)
A data acquisition system (DAS) is the hardware and software that polls every device on a solar or storage site and records the readings on a fixed interval with a trustworthy timestamp.
Read more
Data logger
A data logger is the device on a solar or storage site that polls inverters, meters, and sensors over Modbus or other protocols and forwards the readings to a monitoring platform.
Read more
Dispatch algorithm
A dispatch algorithm is the control logic inside an energy management system that decides what a battery does, such as charging in cheap hours or holding a facility under a demand ceiling.
Read more
EMS run mode
An EMS run mode is the state an energy management system is started in, which decides whether its commands reach real equipment.
Read more
Energy management system (EMS)
An energy management system (EMS) is the software that decides when a battery charges, when it discharges, and how much power it moves.
Read more
Grid forming inverter
A grid forming inverter sets its own voltage and frequency and can hold up a microgrid alone, while a grid following inverter synchronizes to a voltage that already exists.
Read more
Historian
A historian is the time series database that stores every measurement and event a SCADA or energy management system collects, so operators can chart, audit, and report on what the plant did.
Read more
Inverter based resource (IBR)
An inverter based resource (IBR) is a generating or storage resource, such as solar PV, wind, or a battery, that connects to the grid through power electronics rather than a rotating machine.
Read more
Islanding
Islanding is the condition in which a solar or storage system keeps energizing a section of the electrical system after it has been disconnected from the utility grid.
Read more
Microgrid
A microgrid is a group of interconnected loads and energy resources within a defined electrical boundary that acts as a single controllable entity and can connect to or disconnect from the grid.
Read more
Power conversion system (PCS)
A power conversion system (PCS) is the bidirectional inverter that converts a battery’s DC power to AC for the grid and back again to charge it.
Read more
Power plant controller (PPC)
A power plant controller (PPC) is the real time controller that holds a solar or storage plant at its setpoint or utility command at the point of interconnection.
Read more
SCADA
SCADA (supervisory control and data acquisition) is the system that polls a site’s devices, raises alarms, stores history, and relays telemetry to the utility, without running any optimization.
Read more
Setpoint
A setpoint is the target value a controller sends to a device, such as the active power in kilowatts an energy management system commands a battery inverter to deliver.
Read more
Site controller
A site controller is the industrial computer at a solar or storage site that runs the energy management system and power plant controller locally, so dispatch continues when the cloud connection drops.
Read more

Grid and interconnection

Ancillary services
Ancillary services are the grid support functions, such as frequency regulation, operating reserves, voltage support, and black start, that a grid operator buys to keep the system stable.
Read more
Curtailment
Curtailment is a reduction in a plant’s output below what it could produce, ordered by the utility or grid operator or required by an export limit at the point of interconnection.
Read more
Frequency droop
Frequency droop is a control rule that changes a plant’s active power in proportion to the grid frequency’s deviation from nominal, raising output when frequency falls and lowering it when frequency rises.
Read more
Frequency regulation
Frequency regulation is a grid service in which a battery follows a signal from the grid operator every few seconds, charging and discharging to hold system frequency at nominal.
Read more
Interconnection agreement (IA)
An interconnection agreement is the contract between a plant owner and the utility or grid operator that sets the technical and operating conditions for connecting the plant to the grid.
Read more
Point of interconnection (POI)
The point of interconnection (POI) is the electrical location where a solar or storage plant connects to the utility system and where its grid code compliance is measured.
Read more
Ramp rate control
Ramp rate control limits how fast a plant’s active power may change, in megawatts or kilowatts per minute, so a cloud passing or a dispatch step does not shock the grid.
Read more
Volt-var control
Volt-var control adjusts a plant’s reactive power as a function of measured voltage, absorbing reactive power when voltage is high and injecting it when voltage is low.
Read more

Battery metrics

C-rate
C-rate is the rate at which a battery is charged or discharged relative to its capacity, where 1C empties the battery in one hour and 0.5C empties it in two.
Read more
Depth of discharge (DoD)
Depth of discharge (DoD) is the share of a battery’s capacity that has been withdrawn, so a battery at 30 percent state of charge is at 70 percent depth of discharge.
Read more
Power rating and energy capacity
Power rating, in kW or MW, is how much a battery can deliver at one moment; energy capacity, in kWh or MWh, is how much it can deliver in total before it is empty.
Read more
Round trip efficiency (RTE)
Round trip efficiency (RTE) is the energy a battery returns divided by the energy put into it over a full charge and discharge cycle, measured at the AC terminals.
Read more
State of charge (SOC)
State of charge (SOC) is the energy remaining in a battery expressed as a percentage of its usable capacity, with 100 percent full and 0 percent empty.
Read more
State of health (SOH)
State of health (SOH) is a battery’s present capacity, and sometimes its internal resistance, expressed as a percentage of its value when new.
Read more
Storage duration
Storage duration is a battery’s energy capacity divided by its power rating, in hours: a 2 MW, 8 MWh system is a four hour battery.
Read more

Economics and tariffs

Behind the meter (BTM)
Behind the meter describes solar or storage installed on the customer’s side of the utility meter, serving the site’s own load and lowering its bill.
Read more
Demand charge
A demand charge is the part of a commercial electricity bill priced in dollars per kilowatt on the highest average power the facility drew in any single interval, usually fifteen minutes, during the billing period.
Read more
Energy arbitrage
Energy arbitrage is charging a battery when electricity is cheap and discharging it when electricity is expensive, earning the price difference less the round trip losses.
Read more
Front of the meter (FTM)
Front of the meter describes solar or storage connected directly to the utility or transmission system, selling energy and services into markets rather than serving one customer’s load.
Read more
Load forecasting
Load forecasting is predicting how much power a facility or grid will draw in coming intervals, from historical meter data, weather, schedules, and calendar effects.
Read more
Peak shaving
Peak shaving is discharging a battery during the intervals when a facility draws the most power from the grid, so its measured peak demand and the demand charge billed on it are lower.
Read more
Revenue stacking
Revenue stacking is earning from several storage applications with one battery, such as demand charge reduction, arbitrage, frequency regulation, and backup, by allocating its state of charge among them.
Read more
Solar self consumption
Solar self consumption is storing surplus solar generation in a battery during the day and using it on site later, instead of exporting it to the grid at a low price.
Read more
Time of use tariff (TOU)
A time of use tariff is an electricity rate that charges different prices for energy, and often for demand, depending on the hour, the day of the week, and the season.
Read more

Monitoring and performance

Availability
Availability is the share of time a solar or storage plant, or a piece of its equipment, was able to operate, usually reported as a percentage over a month or a year.
Read more
Capacity factor
Capacity factor is the energy a plant produced over a period divided by the energy it would have produced running at full rated power the whole time.
Read more
Performance ratio (PR)
Performance ratio (PR) is a solar plant’s actual energy output divided by the output expected from the measured irradiance at nameplate rating, a dimensionless measure of how well the plant converts sunlight.
Read more

Standards, protocols, and programs

DNP3
DNP3 is the SCADA protocol, standardized as IEEE 1815, that utilities use to exchange time stamped measurements, events, and controls between a control center and outstations such as a plant controller.
Read more
IEC 62443
IEC 62443 is the international series of standards for cybersecurity of industrial automation and control systems, covering the asset owner, the system integrator, and the product supplier.
Read more
IEEE 1547
IEEE 1547 is the standard for interconnecting distributed energy resources, such as rooftop and commercial solar and batteries, with distribution systems.
Read more
IEEE 2800
IEEE 2800 is the standard that sets minimum interconnection and performance requirements for inverter based resources, such as solar, wind, and batteries, connecting to transmission and subtransmission systems.
Read more
Modbus
Modbus is the open master and slave protocol that most inverters, meters, and battery systems use to expose their readings and accept commands as numbered registers.
Read more
MQTT
MQTT is a lightweight publish and subscribe messaging protocol in which devices publish readings to topics on a broker and any authorized subscriber receives them.
Read more
NERC CIP
NERC CIP is the set of mandatory Critical Infrastructure Protection reliability standards that govern the cybersecurity of the bulk electric system in North America.
Read more
Performance Data Provider (PDP)
A Performance Data Provider (PDP) is a company approved by the Self Generation Incentive Program to collect metered data from an incentivized storage system and report it to the program administrator.
Read more
Self Generation Incentive Program (SGIP)
The Self Generation Incentive Program (SGIP) is the California program that pays incentives for behind the meter energy storage and other distributed generation, with monitoring and performance rules attached.
Read more
SunSpec Modbus
SunSpec Modbus is an open information model that standardizes the Modbus register maps of solar inverters, meters, and storage systems, so one driver can read many brands.
Read more
UL 9540
UL 9540 is the safety standard for energy storage systems and equipment, and UL 9540A is the test method that measures how fire propagates between battery cells, modules, and units.
Read more

Operations and security

Audit log
An audit log is the tamper evident record of who did what in a control system and when, covering logins, configuration changes, mode switches, and every setpoint written.
Read more
Commissioning
Commissioning a storage site in an EMS is describing the plant to the software: its devices, how they are wired, which logic dispatches them, what the tariff is, and which systems may read the result.
Read more
Event log
An event log is the time ordered record of what a control system noticed: alarms raised and cleared, devices lost and recovered, mode changes, and limits reached.
Read more
Role based access control (RBAC)
Role based access control (RBAC) grants each user of a control system the permissions of a role, such as viewer, operator, or administrator, rather than individual rights.
Read more
Vendor agnostic
A vendor agnostic energy management system controls batteries, inverters, and meters from any manufacturer through open protocols, instead of only the hardware its maker sells.
Read more